Your value added distributor · Kitchener, ON · 519-745-1926 Open a trade account
Eaton

Part number 9PXM8S4K-PD

,

Eaton 9PXM UPS 4-16kVA 208-240V 14U

  • Keeps equipment running during outages to allow time for file saves and safe shutdown
  • Exclusive ABM technology with 3-stage charging increases internal battery life by 50%
  • Included NETWORK-M3 Gigabit network card enables full remote access and control
  • N+X redundancy for power and logic eliminates system-level single point of failure
  • Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases

Available on backorder

Sign in to see your trade price and order online, or request a quote.

Datasheet (PDF)
New to Primespec? Open a trade account →
SKU: 9PXM8S4K-PD Categories: , Brand:

Features

Modular, Scalable Battery Backup for Edge Data Centers and Industrial/Commercial Applications
This 9PXM online double-conversion UPS system is superlative power management. Rugged enough to stand up to mission-critical applications, the 9PXM8S4K-PD’s compact footprint and N+X redundancy make it a valuable UPS system for colocation and edge data centers, as well as industrial/commercial applications, including retail, financial, government and education. It features hardwired input connections.

Protects Mission-Critical Equipment against Damage, Downtime and Data Loss
The 9PXM8S4K-PD provides reliable power protection against blackouts, brownouts, surges and line noise that can damage valuable IT equipment or destroy data. It includes a 14U cabinet, one split-phase 4kVA power module, two internal battery modules (per slot) and a NETWORK-M3 Gigabit network card. 

UPS Has a Power Range up to 12kVA
The UPS cabinet accommodates up to four hot-swappable 4kVA power modules (9PXMSPPM, extras sold separately) total for 12kVA N+X redundancy that eliminates system-level single point of failure. All power modules share the load requirements equally, even if one power module fails or is removed.

Expandable Internal Battery Backup Keeps You Operational Through Power Outages
The UPS cabinet requires two hot-swappable extended battery modules (9PXMBAT, extras sold separately) per slot. The valve regulated lead acid (VRLA) battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Exclusive ABM® technology increases battery life by 50 percent and closely monitors battery health to provide advanced notice when batteries need replacing.

Included Gigabit Network Interface Offers 24/7 Remote Access
The NETWORK-M3 Gigabit network card enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. UPS firmware can also be flashed remotely through the NETWORK-M3 without dropping the load, so you don’t have to plan for downtime. The card meets both UL 2900-1 and IEC 62443-4-2 standards for cybersecurity, which were developed to address the vulnerability of connected devices to known malware/exploits and to protect business from these risks. The optional Environmental Monitoring Probe Gen 2 (EMPDT1H1C2, sold separately) provides a variety of environmental monitoring capabilities, including temperature and humidity conditions.

NEMA Outlets Protect Your Connected Components
Two L6-30R and four 5-20R outlets provide connected equipment with pure sine wave AC output and allow you to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise.

Intuitive Control Panel Keeps You Informed at a Glance
The UPS control panel includes a graphical LCD, light indicators and function buttons. The control panel provides data and control for the UPS, load status, events, measurements and settings.

Advanced Communications Ports Allow for Automatic Saves and Shutdowns
RS-232 and USB ports connect to a serial-enabled or USB-enabled device for a variety of communication options (cables are included). The EPO and ROO connectors permit emergency shutdown or remote restart of all connected equipment. By adding the optional RELAY-MS interface card (sold separately), a dry-contact relay port can be programmed through the LCD to provide reliable communications to automation and industrial components.

Versatile Installation Options
You can install the 9PXM8S4K-PD in 14U of space in an EIA-standard 19-inch rack using the optional rackmount kit (9PXMRK2, sold separately). Leveling feet and a caster tray are included for secure floor installation.

TAA-Compliant for GSA Schedule Purchases
The 9PXM8S4K-PD is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.

Package Includes

  • 9PXM8S4K-PD 9PXM 4000VA 3600W 208/240V Online Double-Conversion UPS
  • 9PXMSPPM 9PXM split-phase power module
  • (2) 9PXMBAT 9PXM internal battery modules
  • NETWORK-M2 Gigabit network card
  • Owner’s manual

Overview
UPC Code786689053420
UPS TypeOn-Line
Input
Input PhaseSingle-Phase
Rated input current (Maximum Load)125A
Nominal Input Voltage(s) Supported110V AC; 120V AC; 127V AC; 208V AC; 220V AC; 240V AC
UPS Input Connection TypeHardwire
Maximum Input Amps125
Input Frequency50-70 Hz
Input Plug TypeHard-wire
Power Factor (Input)0.99
Output
Output Capacity (VA)4000
Output Capacity (kVA)4
Output Capacity (Watts)3600
Output Capacity (kW)3.6
Output Capacity DetailsScalable output capacity from 4kVA to 12kVA
Power Factor0.9
Crest Factor3:1
Nominal Voltage Details110V/220V, 120V/208V, 120V/240V, 127V/220V
Frequency Compatibility50 / 60 Hz
Output AC Waveform (AC Mode)Pure Sine wave
Output AC Waveform (Battery Mode)Pure Sine wave
Nominal Output Voltage(s) Supported110V; 120V; 127V; 208V; 220V; 240V
Output Receptacles(4) 5-20R; (2) L6-30R
Individually Controllable Load BanksNo
Battery
Battery TypeValve Regulated Lead Acid (VRLA)
Runtime Full Load (min.)6 min. (3600W)
Runtime Half Load (min.)14 min. (1800W)
Expandable RuntimeYes
Expandable Runtime Description9PXMBAT (2 required per slot). Additional extended runtime options are available. See pg. 8 of the 9PXM brochure under Documents & Downloads for more details.
DC System Voltage (VDC)120 per battery string
Battery AccessBattery access door
Internal UPS Replacement Battery Cartridge9PXMBAT
Battery Replacement DescriptionHot-swappable internal batteries and extended battery modules (EBMs)
Battery ManagementABM technology (3-stage charging extends battery service life by 50% and provides advance warning for battery replacement)
User Interface, Alerts & Controls
Front Panel LCD DisplayLCD graphical display
SwitchesRPO / ROO
Alarm Cancel OperationPress ESC to silence the alarm
Audible AlarmAudible alarm indicates utility failure, low-battery, overload, other UPS/Battery fault or remote shutdown conditions
LED Indicators4 status-indicating LEDs
Surge / Noise Suppression
EMI / RFI AC Noise SuppressionYes
AC Suppression Response Time0 ms
Physical
Primary Form FactorRackmount; Tower
Rack Height14U
Cooling MethodFan
Form Factors SupportedRack/Tower
Included Battery Pack Weight (lbs.)33
Included Battery Pack Weight (kg)14.97
Installation Form Factors Supported with Included AccessoriesTower
Maximum Device Depth (cm)88.90
Maximum Device Depth (in.)35
Maximum Device Depth (mm)889
Minimum Required Rack Depth (cm)96.52
Minimum Required Rack Depth (inches)38
Minimum Required Rack Depth with External Battery Pack (cm)97
Minimum Required Rack Depth with External Battery Pack (in.)38
Minimum Required Rack Depth without External Battery Pack (cm)97
Minimum Required Rack Depth without External Battery Pack (in.)38
Optional Mounting Accessory Notes9PXMRK2 - Four post rail kit
Primary UPS Depth (mm)889
Primary UPS Height (mm)635
Primary UPS Width (mm)445
UPS Power Module Weight (kg)10.21
UPS Power Module Weight (lbs.)22.5
Unit Dimensions (hwd / in.)25.000 x 17.500 x 34.500
Unit Weight (lbs.)229.000
Unit Weight (kg)103.87
Environmental
Operating Temperature Range32° to 104°F (0° to 40°C)
Relative Humidity5-95% non-condensing
AC Mode Efficiency Rating (100% Load)94
AC Economy Mode Efficiency Rating (100% Load)97
Communications
Network Management CardsNETWORK-M2; INDGW-M2 ; RELAY-MS
Communications InterfaceRS-232; USB
Features & Specifications
High Availability UPS FeaturesHot swappable batteries; Hot swappable UPS power module; Remote management
Applications
UPS ApplicationsMission Critical Applications
Standards & Compliance
Product CertificationsEN 62040-2; IEC 60950-1; UL Listed; cUL Listed; EN 62040-1; IEC 61000; ICES (Canada)
Product ComplianceFCC (USA); RoHS; CE (Europe); Trade Agreements Act (TAA)
Warranty & Support
Product Warranty Period (U.S. & Canada)2-year limited warranty
Shipping
Shipping weight229 lbs
Shipping dimensions (L × W × H)34.5 × 17.5 × 25 in
Shopping Cart
Scroll to Top